SECOVAC 2102
Stat Zap 2102
- ESD Static Shield Film
- Conductive Buried Shield layer between two polymeric plastic layers; exposed surfaces are static dissipative
- Contains no Amines and is N-Octanoic acid free
- Polycarbonate compatible, humidity independent and heat sealable
- Meets requirements of MIL-PRF-81705-D, Type 111
Electrical Properties:
| Test Method | Anti Static Values | |
|---|---|---|
| Static Decay Rate | FTMS 101C Method 4046.1 | <0.03 seconds |
| Surface Resistivity | ASTM-D-267/ESD S11.31 | <10(10) ohms/sq. |
Physical Properties:
| Test Method | Unit of Measure | Typical Values | |
|---|---|---|---|
| Color | Silver | ||
| Thickness | .0031 | ||
| Yield | sq in/lb(+/-5%) | 8750 | |
| Tensile Strength | ASTM D882-83 Method A | psi | MD 6500 |
| psi | MD 790 | ||
| Tear Strength (Notched) | ASTM D 1004-66 | lbs | |
| MD | 3.0 | ||
| TD | 2.5 | ||
| Burst Strength | FTMS 191 C Method 6122 | psi | 70 |
| Puncture Strength | FTMS 101 C Method 2065.1 | lbs | 2.5 |
| Heat Seal Strength | ASTM D 1876-72 | lbs/width | >10 |
| M.V.T.R | ASTMF F1249 | gms @100° /90% | >16 |
| R.H./100 in² /24 hrs | .35 |
The value shown above were based upon the information supplied to Seco Industries. Products users should make his or her own test to determine the suitability of the information and conclusions therein. No salesperson, representative or agent of Seco Industries is authorized to give any guarantee, warranty or make any representation contrary to the above.